Building Elements Schema

This page defines the data model used to define all building element types.

Wall Types

Walls types are separated by category: External, Internal or Known U-Value.

External walls

A wall that separates the property from the outside.

Field NameUnitRequiredDefault Data Source
Wall name-☑️
Age band-☑️
Construction type-☑️
Additional insulation-☑️
U-valueW/m².KRdSAP 10 Tables 6 to 10
Thermal bridgingW/m².KRdSAP 10 Table 21

Internal walls

A wall that partitions rooms within the same property.

Field NameUnitRequiredDefault Data Source
Wall name-☑️
Internal wall construction-☑️
U-valueW/m².KDHDG 2026 Table 2-36
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Party walls

A wall that separates the property from a neighbouring building.

Field NameUnitRequiredDefault Data Source
Wall name-☑️
Construction type-☑️
U-valueW/m².KRdSAP 10 Table 15
Thermal bridgingW/m².KRdSAP 10 Table 21

Known U-value walls

A wall that has a measured or design U-value.

Field NameUnitRequiredDefault Data Source
Wall name-☑️
U-valueW/m².K☑️
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Floor Types

Floors types are separated by category: Ground, Exposed, Internal or Known U-Value.

Ground floors

A floor that separates the property from the ground. Can be either a solid or suspended floor

Field NameUnitRequiredDefault Data Source
Floor name-☑️
Age band-☑️
Floor construction-☑️
Floor insulation-☑️
Insulation thicknessmm
External wall construction-☑️
External wall thicknessmm
U-valueW/m².KRdSAP 10 Section 5.12 + Table 3
Thermal bridgingW/m².KRdSAP 10 Table 21

Exposed floors

A floor that separates the property from an unheated space (e.g. garage) or outside air (flying freehold).

Field NameUnitRequiredDefault Data Source
Floor name-☑️
Age band-☑️
Insulation level-☑️
U-valueW/m².KRdSAP 10 Table 20
Thermal bridgingW/m².KRdSAP 10 Table 21

Internal floors

A floor that separates different storeys within the same property.

Field NameUnitRequiredDefault Data Source
Floor name-☑️
Internal floor construction-☑️
U-valueW/m².KDHDG 2026 Table 2-45
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Party floors

A floor that separates different different flats/apartments or maisonettes.

Field NameUnitRequiredDefault Data Source
Floor name-☑️
Internal floor construction-☑️
U-valueW/m².KDHDG 2026 Table 2-45
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Known U-value floors

A floor that has a measured or design U-value.

Field NameUnitRequiredDefault Data Source
Floor name-☑️
U-valueW/m².K☑️
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Ceiling and Roof Types

Ceiling and roof types are separated by category: External, Internal or Known U-Value.

External ceilings

A ceiling that separates the property from a loft or the outside air.

Field NameUnitRequiredDefault Data Source
Ceiling name-☑️
Age band-☑️
Roof type-☑️
Insulation thicknessmm☑️
U-valueW/m².KRdSAP 10 Table 16, 17 or 18
Thermal bridgingW/m².KRdSAP 10 Table 21

Internal ceilings

A ceiling that separates different storeys within the same property.

Field NameUnitRequiredDefault Data Source
Ceiling name-☑️
Internal ceiling construction-☑️
U-valueW/m².KDHDG 2026 Table 2-45
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Party ceilings

A ceiling that separates different different flats/apartments or maisonettes.

Field NameUnitRequiredDefault Data Source
Floor name-☑️
Internal floor construction-☑️
U-valueW/m².KDHDG 2026 Table 2-45
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Known U-value ceilings

A ceiling that has a measured or design U-value.

Field NameUnitRequiredDefault Data Source
Ceiling name-☑️
U-valueW/m².K☑️
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Door Types

Door types are separated by category: External, Internal or Known U-Value.

Glazed Doors

When a door contains more than 60% glazing, it should be added as a window type to produce an accurate U-value.

However a window with less than 60% glazing is not a door; a door always provides a means of entry to the property.

External doors

A door that separates the property from the outside.

Field NameUnitRequiredDefault Data Source
Door name-☑️
Age band-☑️
Opens to-☑️
U-valueW/m².KRdSAP 10 Table 26
Thermal bridgingW/m².KRdSAP 10 Table 21

Internal doors

A door that separates rooms within the same property.

Field NameUnitRequiredDefault Data Source
Door name-☑️
Internal door construction-☑️
U-valueW/m².KDHDG 2026 Table 2-42
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Known U-value doors

A door that has a measured or design U-value.

Field NameUnitRequiredDefault Data Source
Door name-☑️
U-valueW/m².K☑️
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Window Types

Window types are separated by category: External, Internal or Known U-Value.

External windows

A window that separates the property from the outside.

Field NameUnitRequiredDefault Data Source
Window name-☑️
Window type-☑️
Glazing type-☑️
Frame type-☑️
Year installed-☑️ †
Permanent shutters-
U-valueW/m².KRdSAP 10 Table 24 or 25
Thermal bridgingW/m².KRdSAP 10 Table 21

† only applicable to double or triple glazed windows

Internal windows

A window or glass partition that separates rooms within the same property.

Field NameUnitRequiredDefault Data Source
Window name-☑️
Internal glazing type-☑️
U-valueW/m².KDHDG 2026 Table 2-42
Thermal bridgingW/m².KDHDG 2026 Table 2-9

Known U-value windows

A window that has a measured or design U-value.

Field NameUnitRequiredDefault Data Source
Window name-☑️
U-valueW/m².K☑️
Thermal bridgingW/m².KDHDG 2026 Table 2-9