Property Schema
This page defines the data model used to define a Property.
Building Information
Field Name | Unit | Required | Default Data Source |
---|---|---|---|
Reference | - | ✳️ | |
Postcode | - | ✳️ | |
Altitude | m | ✳️ | Google Elevation API |
Design external air temperature | °C | ✳️ | CIBSE Guide A Table 2.5 (99.6%) |
Mean annual external air temperature | °C | ✳️ | MCS MGD 007 Table B1 |
Heating degree days | - | ✳️ | CIBSE / MET Office |
Dwelling type | - | ✳️ | |
Attachment | - | ✳️ | |
Age band | - | ✳️ | |
Number of occupants | - |
Airtightness method
One of the following airtightness methods is required:
Field Name | Unit | Default Data Source |
---|---|---|
Standard airtightness | - | CIBSE DHDG Table 1.7 |
Design air change rate | 1/h | |
Measured air permeability | m³/m².h | |
↳ Pressure difference | Pa | |
↳ Envelope area | m² | |
↳ Building volume | m³ |
Thermal performance
If a thermal performance test has been selected, the following is required:
Field Name | Unit |
---|---|
Heat transfer coefficient | W/K |
Ventilation Zones
Each unique ventilation zone must be defined. Rooms that share the same ventilation system form a single zone.
Field Name | Required | Default Data Source |
---|---|---|
Number of storeys | ✳️ | |
Number of external facades | ✳️ | Based on attachment |
Number of sheltered sides | ✳️ | |
Ventilation type | ✳️ |